Transfer of analytical methods

Posted by: , Posted on: - Categories: Compliance matters, Good laboratory practice, Good manufacturing practice

Technical transfer of analytical methods, or analytical method transfer (AMT) is a GMP requirement for those involved in contract manufacturing and testing.

The purpose of this post is to provide guidance to manufacturers and contract testing laboratories for the process of transferring a method for outsourcing of testing. Whilst not included within this post, the requirements of EU GMP Chapter 7 should also be met.

Analytical method transfer is a verification process which has much in common with the validation activities described in EU GMP Annex 15 and the guidance it contains provides a useful framework to work from.

The type of AMT most frequently seen on inspection is comparative testing. Comparative AMT requires both the transferring and receiving laboratory to perform an agreed number of analyses on the same manufacturing batch and compare the data generated within both laboratories.

There should be a formal process for the introduction of new methods which allows the receiving laboratory to demonstrate that they can perform the analytical method effectively and reproducibly. It should also ensure that the transfer protocol covers all critical quality attributes and method parameters considered important for maintaining the method’s validated state and ensuring product quality can be consistently met by the receiving laboratory.

Regulatory compliance is a shared responsibility and a collaborative approach will give both the transferring and receiving laboratories confidence in the data generated after the AMT is completed. For instance, performing a gap analysis would allow both parties to identify additional validation activities that may be required, and receiving laboratories should identify whether they have the staff and testing capacity to perform testing prior to AMT commencing.

The use of risk management principles for AMT can be advantageous when identifying which tests to transfer and the number of tests to be performed. This approach is particularly useful where similar products are already tested using similar techniques.

Having performed the AMT - successfully or unsuccessfully - a transfer report should be generated.

Finally, here are some common findings around AMT:

  • equipment was not qualified for the range used in the transferred method
  • the impact of differences in equipment was not included in the gap analysis - such as different makes and models of high performance liquid chromatography (HPLC) equipment used at transferring and receiving sites
  • the receiving laboratory did not follow the transfer protocol
  • the method references internal documents from the transferring laboratory which were not available at the receiving laboratory
  • AMT was performed as a single test, on one batch of product: examples being, one single agar plate for a microbiology assay, one dissolution test, one assay test without appropriate justification
  • a single strength was used to transfer methods used for multiple strengths

Don’t miss the next post,  sign up to be notified by email when a new post comes out

Sharing and comments

Share this page

4 comments

  1. Comment by MD. SELIM REZA posted on

    If we would like to perform successful method transfer activity, it should be part of AQbD as follows

    * Contract giver must enter critical quality attributes during its method development and validation
    * Its successful method validation protocol and report containing method precision and intermediate precision linked for AMT to be done.
    *A method transfer protocol and report containing methodology sample preparation, instrumentation, CQA, how much samples to be prepared, number of injections, absorbance for method precision and intermediate precision, acceptance criteria to be included.
    *A quality risk assessment to be raised as part of AMT. Acceptance criteria and CQA to be monitored very strictly for successful ending a AMT project.

  2. Comment by bridgemedsolutions posted on

    thanks for sharing such a usefull blog

  3. Comment by Krishnendu Singha posted on

    Should transferring laboratory be covered under GMP certificate?

    • Replies to Krishnendu Singha>

      Comment by Chris Smith posted on

      Analytical method transfer can be performed without a GMP Certificate but the process should be performed in compliance with GMP guidance and a GMP Certificate must be in place before the method can be used to carry out finished product testing.